12/8/2022 0 Comments Itrace abberometerMoving the incident beam along a certain pupillary meridian (indicated by arrows in the figure) will result in a reflected beam that goes in the same or opposite direction as the incident beam. However, in a hyperopic eye the reflection is directed to the opposite side of the pupil. Because the retina can be considered a spherically concave mirror (reflecting about 4% of incident light), the beam is reflected back in more or less the original direction in a myopic eye. It uses focal shift in a different way, starting with the observation that the retinal image of a light beam coming from a superior direction is located below the optical axis in a myopic eye and above the optical axis in a hyperopic eye. The automatic retinoscope is an automated version of the handheld retinoscope and is implemented in an objective, serial, and double-pass fashion. The uncomplicated nature of the technique makes it robust for extreme aberrations. The x-y scanner, comprising 2 separate scanners for the x- and y-directions, repeatedly moves the beam to a new entry position until homogeneously spread measurements are available for the whole pupil area. Using a beam splitter and lens, the retinal image is captured on a linear array of photodetectors and is made available for further processing. Once in the eye, local aberrations in the beam's entry position cause a focal shift of the retinal image with respect to a certain reference position. Ray tracing uses a narrow laser beam that is directed into the eye parallel to the eye's line of sight by means of an x-y scanner. doi: 10.1016/s0886-3350(01)01279-2.The ray tracing principle is a serial, double-pass method using forward projection that can be implemented in both an objective and subjective manner. Journal of Cataract and Refractive Surgery. Cyclotorsion: a possible cause of residual astigmatism in refractive surgery. Astigmatism management in cataract surgery with the AcrySof toric intraocular lens. Toric intraocular lens versus opposite clear corneal incisions to correct astigmatism in eyes having cataract surgery. Mendicute J., Irigoyen C., Ruiz M., Illarramendi I., Ferrer-Blasco T., Montés-Micó R. #Itrace abberometer archiveGraefe’s Archive for Clinical and Experimental Ophthalmology. Limbal relaxing incision during cataract extraction versus photoastigmatic keratectomy after cataract extraction in controlling pre-existing corneal astigmatism. Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes. #Itrace abberometer manualIt can eliminate the potential systematic errors resulting from varying head positions during the preoperative keratometry measurement and from manual marking. The TRP marking method using the iTrace aberrometer is simple and accurate for preoperative marking of toric IOLs. The mean toric IOL misalignment was lesser but without significance in the TRP marking group than in the SHM marking group after 3 postoperative months (2.66° ± 1.42° versus 3.29° ± 1.67° P=0.295). There was no statistically significant difference in BCVA, UDVA, preexisting corneal astigmatism, or residual astigmatism between the groups before or after surgery ( P > 0.05). The follow-up duration was 3 months after cataract surgery.įifteen eyes of 15 patients were in the TRP marking group and 15 eyes of 15 patients in the SHM marking group. TRP marking involved marking three points randomly in the corneal limbus of the patients and accurately marking the horizontal meridian was not required. All patients were prospectively randomized into the TRP marking group or slit-lamp horizontal meridian (SHM) marking group. Thirty eyes of 30 patients undergoing cataract surgery with coexisting corneal astigmatism of over 1.0 D were included in this study. Prospective, randomized comparative trial. Department of Ophthalmology, Guangdong Eye Institute, Guangdong Academy of Medical Sciences, Guangdong Provincial People's Hospital, Guangzhou, China. To evaluate the clinical outcome of the three-random-point (TRP) marking method for toric intraocular lens (IOL) alignment using the iTrace aberrometer (Tracey Technologies Corp., Houston, TX).
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |